Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.252
Filtrar
1.
Medicine (Baltimore) ; 103(16): e37894, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38640277

RESUMEN

RATIONALE: The novel coronavirus of 2019 (COVID-19) has inflicted significant harm on the cardiovascular system. Patients presenting with fatal chronic arrhythmias after severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection are rare, arrhythmia caused by SARS-CoV-2 infection need to be taken seriously. PATIENT CONCERNS: Three female patients were admitted to the hospital with syncopal symptoms. Previously, they had been identified to have COVID-19 infection and none of the patients had a preexisting history of arrhythmia, and upon hospital admission, no electrolyte imbalances associated with arrhythmias were observed. However, following SARS-CoV-2 infection, patients exhibit varying degrees of syncope symptoms. DIAGNOSES: A high-degree atrioventricular block was diagnosed after a comprehensive evaluation of the patient's clinical manifestations and electrocardiogram (ECG) performance. INTERVENTIONS: We performed ECG monitoring of the patient and excluded other causes of arrhythmia. The patient was discharged from the hospital after permanent pacemaker implantation and symptomatic treatment. OUTCOMES: The outpatient follow-ups did not reveal a recurrence of syncope or complications related to the pacemaker in any of the three patients. LESSONS: Some patients did not exhibit any obvious respiratory symptoms or signs following SARS-CoV-2 infection. This suggests that the cardiac conduction system may be the preferred target for some SARS-CoV-2 variants. Therefore, in addition to investigating the causes of malignant arrhythmias, special attention should be paid to SARS-CoV-2 infection in patients with developing arrhythmias. Additionally, permanent pacemaker implantation may be the most suitable option for patients who already have malignant arrhythmias.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Femenino , COVID-19/complicaciones , Síncope/etiología , Arritmias Cardíacas/etiología
2.
Physiol Rep ; 12(8): e16004, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38658324

RESUMEN

Duchenne muscular dystrophy (DMD) is an X-linked recessive myopathy due to mutations in the dystrophin gene. Diaphragmatic weakness in DMD causes hypoventilation and elevated afterload on the right ventricle (RV). Thus, RV dysfunction in DMD develops early in disease progression. Herein, we deliver a 30-min sustained RV preload/afterload challenge to isolated hearts of wild-type (Wt) and dystrophic (Dmdmdx-4Cv) mice at both young (2-6 month) and middle-age (8-12 month) to test the hypothesis that the dystrophic RV is susceptible to dysfunction with elevated load. Young dystrophic hearts exhibited greater pressure development than wild type under baseline (Langendorff) conditions, but following RV challenge exhibited similar contractile function as wild type. Following the RV challenge, young dystrophic hearts had an increased incidence of premature ventricular contractions (PVCs) compared to wild type. Hearts of middle-aged wild-type and dystrophic mice had similar contractile function during baseline conditions. After RV challenge, hearts of middle-aged dystrophic mice had severe RV dysfunction and arrhythmias, including ventricular tachycardia. Following the RV load challenge, dystrophic hearts had greater lactate dehydrogenase (LDH) release than wild-type mice indicative of damage. Our data indicate age-dependent changes in RV function with load in dystrophin deficiency, highlighting the need to avoid sustained RV load to forestall dysfunction and arrhythmia.


Asunto(s)
Arritmias Cardíacas , Distrofina , Contracción Miocárdica , Animales , Masculino , Distrofina/genética , Distrofina/deficiencia , Ratones , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/genética , Disfunción Ventricular Derecha/fisiopatología , Disfunción Ventricular Derecha/genética , Disfunción Ventricular Derecha/metabolismo , Distrofia Muscular de Duchenne/fisiopatología , Distrofia Muscular de Duchenne/genética , Distrofia Muscular de Duchenne/complicaciones , Distrofia Muscular de Duchenne/metabolismo , Ratones Endogámicos mdx , Ratones Endogámicos C57BL
3.
Sci Rep ; 14(1): 9093, 2024 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-38643303

RESUMEN

Post-stroke depression (PSD) is regarded as the consequence of multiple contributors involving the process of cognition, mood and autonomic system, with the specific mechanism unclear yet. As a common type of stroke-heart syndromes, post-stroke arrhythmia shared some common pathogenesis with PSD. We presumed that post-stroke arrhythmia might be an early distinguishable marker for the presence of PSD and aimed to verity their association in this study. Patients with first-ever ischemic stroke were enrolled. The presence of post-stroke ectopic arrhythmia and the symptoms of arrhythmia were recorded with anti-arrhythmia drugs prescribed when necessary. Patients were followed up 3 months later to identify their presence and severity of PSD using Hamilton Depression Scale (HAMD) and also presence and severity of arrhythmia. Characteristics including the prevalence of various types of arrhythmias were compared between PSD and non-PSD groups. The HAMD scores were compared between patients with and without arrhythmia in PSD group. Logistic regression was used to identify the independent predictor of PSD. Patients with PSD had higher prevalence of post-stroke arrhythmia especially newly-detected arrhythmia, symptomatic arrhythmia and poor-controlled arrhythmia. In PSD group, patients of post-stroke arrhythmia had higher scores of HAMD than those without arrhythmia. Presence of newly-detected, symptomatic and poor-controlled arrhythmias were independent predictor of PSD. post-stroke arrhythmia especially newly-detected arrhythmia and symptomatic arrhythmia could be an early predictor of PSD. Successful control of arrhythmia was associated with reduced prevalence and severity of PSD.


Asunto(s)
Isquemia Encefálica , Accidente Cerebrovascular , Humanos , Isquemia Encefálica/complicaciones , Depresión/diagnóstico , Depresión/etiología , Depresión/epidemiología , Accidente Cerebrovascular/epidemiología , Afecto , Arritmias Cardíacas/etiología , Arritmias Cardíacas/complicaciones
4.
J Cardiothorac Surg ; 19(1): 167, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38561765

RESUMEN

BACKGROUND: The implantation of left ventricular assist devices (LVADs) as a bridge to transplantation or as destination therapy in end-stage heart failure patients is frequently complicated by the emergence of ventricular arrhythmias (VAs). These arrhythmias have been implicated in precipitating deleterious clinical outcomes, increased mortality rates and augmented healthcare expenditures. CASE PRESENTATION: We present a challenging case of a 49-year-old male with a history of dilated cardiomyopathy who received an LVAD. Post-implantation, the patient suffered from intractable VAs, leading to multiple rehospitalizations and hemodynamic deterioration. Despite exhaustive medical management and electrical cardioversion attempts, the patient's VAs persisted, ultimately necessitating prioritization for cardiac transplantation. DISCUSSION: This case highlights the challenges in managing VAs in LVAD patients and the importance of multidisciplinary collaboration. While pharmacological intervention is the initial strategy, catheter ablation may be considered in selected cases when medication is insufficient. In instances of intractable VAs, expeditious listing for heart transplantation as a high-priority candidate is advisable when feasible.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Masculino , Humanos , Persona de Mediana Edad , Corazón Auxiliar/efectos adversos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Arritmias Cardíacas/etiología , Hemodinámica , Cardioversión Eléctrica , Resultado del Tratamiento
5.
Open Heart ; 11(1)2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38569668

RESUMEN

AIMS: Some patients with cardiac dystrophinopathy die suddenly. Whether such deaths are preventable by specific antiarrhythmic management or simply indicate heart failure overwhelming medical therapies is uncertain. The aim of this prospective, cohort study was to describe the occurrence and nature of cardiac arrhythmias recorded during prolonged continuous ECG rhythm surveillance in patients with established cardiac dystrophinopathy and relate them to abnormalities on cardiac MRI. METHODS AND RESULTS: A cohort of 10 patients (36.3 years; 3 female) with LVEF<40% due to Duchenne (3) or Becker muscular (4) dystrophy or Duchenne muscular dystrophy-gene carrying effects in females (3) were recruited, had cardiac MRI, ECG signal-averaging and ECG loop-recorder implants. All were on standard of care heart medications and none had prior history of arrhythmias.No deaths or brady arrhythmias occurred during median follow-up 30 months (range 13-35). Self-limiting episodes of asymptomatic tachyarrhythmia (range 1-29) were confirmed in 8 (80%) patients (ventricular only 2; ventricular and atrial 6). Higher ventricular arrhythmia burden correlated with extent of myocardial fibrosis (extracellular volume%, p=0.029; native T1, p=0.49; late gadolinium enhancement, p=0.49), but not with LVEF% (p=1.0) on MRI and atrial arrhythmias with left atrial dilatation. Features of VT episodes suggested various underlying arrhythmia mechanisms. CONCLUSIONS: The overall prevalence of arrhythmias was low. Even in such a small sample size, higher arrhythmia counts occurred in those with larger scar burden and greater ventricular volume, suggesting key roles for myocardial stretch as well as disease progression in arrhythmogenesis. These features overlap with the stage of left ventricular dysfunction when heart failure also becomes overt. The findings of this pilot study should help inform the design of a definitive study of specific antiarrhythmic management in dystrophinopathy. TRIAL REGISTRATION NUMBER: ISRCTN15622536.


Asunto(s)
Medios de Contraste , Insuficiencia Cardíaca , Humanos , Femenino , Estudios Prospectivos , Estudios de Cohortes , Proyectos Piloto , Gadolinio , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Imagen por Resonancia Magnética , Antiarrítmicos/uso terapéutico , Insuficiencia Cardíaca/tratamiento farmacológico
11.
J Cardiothorac Surg ; 19(1): 230, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627733

RESUMEN

BACKGROUND: The results of the use of del-Nido(DN) solution using a different method or crystalloid blood cardioplegia in coronary bypass patients were compared. We aimed to investigate the effects on intraoperative and postoperative arrhythmias, arrhythmia durations and early results. METHODS: The study included 175 patients using crystalloid blood cardioplegia (Group 1) and 150 patients using DN solution(Group 2). In the DN group, 75% of the calculated plegia dose was given first. the remaining part was applied by giving from grafts. Intraoperative/postoperative data were compared. RESULTS: There was no significant difference between the groups in terms of demographic characteristics. Preop troponin level was similar.(p = 0.190) However, there was a statistical difference between the postoperative 6th hour.(p = 0.001) There was no difference in troponin values at the postoperative 24th hour. (p = 0.631) Spontaneous rhythm occurred at the cardiopulmonary by pass (CPB) weaning stage in most of the patients in Group 2 (95.3%). Although the need for temporary pacing was less in Group 2, it was not significant.(p = 0.282) No patient required permanent pacing. CPB duration, cross clamp times and intraoperative glucose levels, intensive care follow-up times and hospitalization times were found to be shorter in Group 2. Although the postoperative atrial fibrillation frequency was similar (p = 0.261), the time to return to sinus was lower in Group 2.(p = 0.001). CONCLUSION: The use of DN cardioplegia solution provides significant positive contributions to avoid arrhythmias compared to crystalloid blood cardioplegia. DN solution applied with this method may contribute to reducing the anxieties associated with its use in isolated coronary artery bypass surgery.


Asunto(s)
Soluciones Cardiopléjicas , Paro Cardíaco Inducido , Humanos , Soluciones Cristaloides , Paro Cardíaco Inducido/efectos adversos , Soluciones Cardiopléjicas/farmacología , Troponina , Arritmias Cardíacas/prevención & control , Arritmias Cardíacas/etiología , Estudios Retrospectivos
12.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38584394

RESUMEN

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Asunto(s)
Ablación por Catéter , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Resultado del Tratamiento , Cardioversión Eléctrica/efectos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Arritmias Cardíacas/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
13.
Am J Case Rep ; 25: e942381, 2024 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-38431769

RESUMEN

BACKGROUND Idiopathic giant cell myocarditis (IGCM) is an uncommon and frequently fatal type of myocarditis. It primarily affects young individuals and has the potential to result in heart failure and life-threatening arrhythmias. IGCM seems to be dependent on activation of CD4-positive T lymphocytes and can show improvement with treatment aimed at reducing T-cell function. We present a case of a 65-year-old patient who presented with features of acute heart failure refractory to guideline-directed medical therapy (GDMT), due to IGCM. A review of the natural history and treatment of IGCM is also presented. CASE REPORT A 65-year-old woman with multiple comorbidities was admitted to our hospital for ventricular tachycardia in the setting of progressive non-ischemic heart failure, unresponsive to GDMT. This led to further investigation, including an endomyocardial biopsy, which revealed inflammatory infiltration, with multinucleated giant cells and lymphocytes in the absence of granuloma formation, prompting a diagnosis of IGCM. An implantable cardioverter-defibrillator (ICD) was placed for secondary prevention of sudden cardiac death and the patient was initiated on combined immunosuppressive therapy. Owing to numerous comorbidities, she was determined to be unsuitable for a heart transplant. Unfortunately, she eventually died from complications secondary to the disease. CONCLUSIONS IGCM remains a challenging clinical diagnosis with a poor long-term outcome without heart transplantation. This case highlights the importance of considering atypical causes of heart failure in patients who do not respond to conventional therapies. Early recognition and appropriate management, involving medical and interventional approaches, are crucial in improving outcomes for patients with IGCM.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Miocarditis , Femenino , Humanos , Anciano , Miocarditis/diagnóstico , Miocarditis/terapia , Miocarditis/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Trasplante de Corazón/efectos adversos , Arritmias Cardíacas/etiología , Células Gigantes/patología
14.
Heart Fail Clin ; 20(2): 175-188, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38462322

RESUMEN

Heart failure and arrhythmias represent 2 major causes of mortality and morbidity in adults with congenital heart disease. Arrhythmias and heart failure are interdependent, and one may exacerbate the other. Treatment of one also has a positive impact on the other. Management approaches need to be multifaceted, including pharmacotherapy, optimization of hemodynamic status with catheter-based or surgical interventions, and specific management of arrhythmia with device or catheter ablation therapy.


Asunto(s)
Ablación por Catéter , Cardiopatías Congénitas , Insuficiencia Cardíaca , Adulto , Humanos , Cardiopatías Congénitas/terapia , Cardiopatías Congénitas/cirugía , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/cirugía , Ablación por Catéter/efectos adversos
15.
Acta Cardiol ; 79(2): 215-223, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38456718

RESUMEN

BACKGROUND: This study aimed to uncover the diagnostic value of circRNA (Circ)_0051386 in acute ST-segment elevation myocardial infarction (STEMI) and its predictive value for the occurrence of adverse major adverse cardiovascular events (MACEs). METHODS: This study included 166 patients with STEMI and 83 health donors. The expression levels of serum Circ_0051386 in these participants were quantified using real-time quantitative polymerase chain reaction (RT-qPCR). Additionally, the incidence of MACEs during a 6-month follow-up period after percutaneous coronary intervention (PCI) was collected in the STEMI patient cohort. RESULTS: Before and after propensity score matching (PSM), Circ_0051386 all had higher expression levels in the patients with STEMI than the normal subjects (all p < .001)and robust diagnosis values for the STEMI (AUC = 0.766, 0.779). Kaplan-Meier curves showed the high expression Circ_0051386 group had a higher occurrence rate of MACEs during a 6-month follow-up after PCI in patients with STEMI and this phenomenon was confirmed by internal validation (all p < .05). In addition, the multivariate COX regression showed gensini score (HR = 1.020, 95% CI = 1.002 - 1.038, p = .028) and Circ_0051386 (HR = 2.468, 95% CI =1.548-3.935, p < .001)were independent risk factors of the occurrence of MACEs in patients with STEMI after PCI. Pearson analysis presented that Circ_0051386 was positively correlated with gensini scores (r = 0.33), IL-1ß (r = 0.55)and TNF-α(r = 0.41). CONCLUSION: Our study indicated that Circ_0051386 is a biomarker of the diagnostic for STEMI and the predictor of the MACEs in STEMI patients after PCI. Its potential role in STEMI may be the regulation of inflammation in the vascular endothelial.


Asunto(s)
Infarto de la Pared Anterior del Miocardio , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/genética , Infarto del Miocardio con Elevación del ST/cirugía , Intervención Coronaria Percutánea/efectos adversos , ARN Circular/genética , Arritmias Cardíacas/etiología
16.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38531027

RESUMEN

AIMS: Percutaneous stellate ganglion block (PSGB) through single-bolus injection and thoracic epidural anaesthesia (TEA) have been proposed for the acute management of refractory ventricular arrhythmias (VAs). However, data on continuous PSGB (C-PSGB) are scant. The aim of this study is to report our dual-centre experience with C-PSGB and to perform a systematic review on C-PSGB and TEA. METHODS AND RESULTS: Consecutive patients receiving C-PSGB at two centres were enrolled. The systematic literature review follows the latest Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria. Our case series (26 patients, 88% male, 60 ± 16 years, all with advanced structural heart disease, left ventricular ejection fraction 23 ± 11%, 32 C-PSGBs performed, with a median duration of 3 days) shows that C-PSGB is feasible and safe and leads to complete VAs suppression in 59% and to overall clinical benefit in 94% of cases. Overall, 61 patients received 68 C-PSGBs and 22 TEA, with complete VA suppression in 63% of C-PSGBs (61% of patients). Most TEA procedures (55%) were performed on intubated patients, as opposed to 28% of C-PSGBs (P = 0.02); 63% of cases were on full anticoagulation at C-PSGB, none at TEA (P < 0.001). Ropivacaine and lidocaine were the most used drugs for C-PSGB, and the available data support a starting dose of 12 and 100 mg/h, respectively. No major complications occurred, yet TEA discontinuation rate due to side effects was higher than C-PSGB (18 vs. 1%, P = 0.01). CONCLUSION: Continuous PSGB seems feasible, safe, and effective for the acute management of refractory VAs. The antiarrhythmic effect may be accomplished with less concerns for concomitant anticoagulation compared with TEA and with a lower side-effect related discontinuation rate.


Asunto(s)
Anestesia Epidural , Ganglio Estrellado , Humanos , Masculino , Femenino , Volumen Sistólico , Función Ventricular Izquierda , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Anestesia Epidural/efectos adversos , Anestesia Epidural/métodos , Anticoagulantes/farmacología
17.
J Am Heart Assoc ; 13(6): e032047, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38456399

RESUMEN

BACKGROUND: Current guidelines recommend placing an implantable cardiac defibrillator for patients with cardiac sarcoidosis and a severely impaired left ventricular ejection fraction (LVEF) of ≤35%. In this study, we determined the association between mild or moderate LVEF impairment and fatal ventricular arrhythmic event (FVAE). METHODS AND RESULTS: We retrospectively analyzed 401 patients with cardiac sarcoidosis without sustained ventricular arrhythmia at diagnosis. The primary end point was an FVAE, defined as the combined endpoint of documented ventricular tachycardia or ventricular fibrillation and sudden cardiac death. Two cutoff points for LVEF were used: a sex-specific lower threshold of normal range of LVEF (52% for men and 54% for women) and an LVEF of 35%, which is used in the current guidelines. During a median follow-up of 3.2 years, 58 FVAEs were observed, and the 5- and 10-year estimated incidences of FVAEs were 16.8% and 23.0%, respectively. All patients were classified into 3 groups according to LVEF: impaired LVEF group, mild to moderate impairment of LVEF group, and maintained LVEF group. Multivariable competing risk analysis showed that both the impaired LVEF group (hazard ratio [HR], 3.24 [95% CI, 1.49-7.04]) and the mild to moderate impairment of LVEF group (HR, 2.16 [95% CI, 1.04-4.46]) were associated with a higher incidence of FVAEs than the maintained LVEF group after adjustment for covariates. CONCLUSIONS: Patients with cardiac sarcoidosis are at a high risk of FVAEs, regardless of documented ventricular arrhythmia at the time of diagnosis. In patients with cardiac sarcoidosis, mild to moderate impairment of LVEF is associated with FVAEs.


Asunto(s)
Desfibriladores Implantables , Miocarditis , Sarcoidosis , Masculino , Humanos , Femenino , Función Ventricular Izquierda , Volumen Sistólico , Estudios Retrospectivos , Sarcoidosis/complicaciones , Sarcoidosis/diagnóstico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/complicaciones , Desfibriladores Implantables/efectos adversos , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Miocarditis/complicaciones
18.
Eur Heart J ; 45(14): 1241-1251, 2024 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-38426911

RESUMEN

BACKGROUND AND AIMS: Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. METHODS: All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine-Gray competing risk models. RESULTS: 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6-64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%-5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36-.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%-6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). CONCLUSIONS: Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.


Asunto(s)
Arritmias Cardíacas , Marcapaso Artificial , Humanos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Resultado del Tratamiento , Diseño de Equipo , Marcapaso Artificial/efectos adversos , Sistema de Registros , Estimulación Cardíaca Artificial/efectos adversos
19.
Braz J Med Biol Res ; 57: e13174, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38451608

RESUMEN

There's limited evidence of the potential benefits of cardiopulmonary and metabolic rehabilitation (CPMR) in patients with heart failure with preserved ejection fraction (HFpEF) or mildly reduced ejection fraction (HFmrEF) and coronary artery disease (CAD). The aim of this study was to investigate the impact of CPMR on the myocardial ischemia response (MIR), exercise-induced arrhythmias (EIA), New York Heart Association (NYHA) functional class, heart rate recovery (HRR), Borg CR10 perceived symptoms, and the SF-36 physical and mental health summary scores. A prospective cohort study was conducted with 106 patients undergoing 12 weeks of CPMR who completed two exercise tests pre- and post-CPMR: 1) maximum incremental test (CPX) and 2) submaximal constant load test (SUB). After CPMR, the effects on MIR, EIA, NYHA functional class, and HRR during both tests were analyzed. There was a significant change in NYHA functional classes after CPMR, with 96% of the patients in class I (vs 62% pre-CPMR, P<0.0001), 4% in class II (vs 32%), and none in class III (vs 6%). There was a significant reduction in the frequency of EIA (P<0.05) and MIR (P<0.001) and a significantly improved performance on both CPX and SUB tests (P<0.0001). Lastly, there was significant progress in the recovery metrics like HRR (P<0.0001), the Borg CR10 (P<0.0001), and the SF-36 summary scores (P<0.0001). The CPMR resulted in a significant decrease in EIA, delayed ischemia threshold in CPX and SUB tests, increased functional capacity, and improved quality of life.


Asunto(s)
Enfermedad de la Arteria Coronaria , Insuficiencia Cardíaca , Isquemia Miocárdica , Humanos , Estudios Prospectivos , Calidad de Vida , Volumen Sistólico , Arritmias Cardíacas/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...